Cylinder racking in a medical gas store

Services

Equipment Supplies

Along with the services offered, Medical Engineering Systems can also supply the following equipment on request.

OxygenNitrous oxideEntonoxMedical airSurgical airVacuumAGSS

It may just be a one-off purchase where you don’t wish to set up a new supplier or the ongoing supply of goods without expanding your supplier base to several others.

A

Cylinder Handling and Storage

  • Cylinder trolleys
  • Cylinder racking
  • Cylinder Cages and Stores
B

SOT

  • Flowmeters
  • Regulators
  • Suction controllers
  • Hoses
C

MGPS Test Equipment

  • Medical Gas Test & Commissioning Kit (Analogue or Digital)
  • Flow Rate Pressure Drop
  • AGSS Test Kits
  • Anti-Confusion Probes & NIST
  • Particulate and Purging Test Kit
  • Pressure Drop Test Kit
Terminal unit test rig with pressure gauge
D

Exposure to Waste Anaesthetic Gas Personal Monitoring

  • Nitrous Oxide Personal Monitor
  • Gas Anaesthetic Agent Personal Monitor
E

N2O Manifold Decommissioning Rundown Adaptors

To prepare for the process of decommissioning Nitrous Oxide manifolds and pipelines and reduce the need to send full cylinders back to the supplier. It is cost effective to have a staggered reduction of the number of cylinders on site while maintaining the functionality of the manifold system in the run up to isolation and removal. Follow these steps to utilise the remaining N2O on site, the adaptor kit will allow a staggered reduction and return of N2O empty cylinders back to the supplier without replenishing stock levels and also allow for a quick and easy reversal if required.

The steps

  1. Assess the size of your existing manifold(s). Is it a 2 x 6 or 2 x 8?
  2. How often does one bank of cylinders on the manifold get changed?
  3. The next time one bank goes empty, remove the empty cylinders and fit the tailpipe blanking adaptors to some of the tailpipes and fit the rest with cylinders from the spare stock on site.
  4. Issue a notice to your gas supplier to collect Empty “G” or “J” Nitrous Oxide cylinders but “DO NOT REPLACE” with full cylinders.
  5. Repeat this step when the second bank runs empty.
  6. Thus, converting the manifold from a 2 x 6 to a 2 x 3, 2 x 2 or 2 x 1 as deemed appropriate.
  7. Continue to run down stock and then maintain minimum stock on “full for Empty” or manual ordering until decommission is completed.
  8. In the countdown to decommissioning your N2O manifold notify your gas supplier with any changes to stock levels of smaller “F” or “E” N2O cylinders you may require.

NOTE: The removal of the piped N2O and manifold is in conjunction with ceasing to use N2O apart from by exception and occasional use, therefore there should not be an automatic or significant increase of smaller cylinder numbers.

Benefits of using rundown adaptor

  • Use existing gas and reduce stock levels safely.
  • Keeps tailpipes system clean and sealed.
  • Easy to complete and reversable if an increase to cylinder number is required through miscalculation.
  • Maintains auto changeover and continuity of supply.
  • Stepped reduction and use rented cylinder and gas.
Oxygen manifold and pressure regulators
F

Wall Cylinder Brackets

Creating a safe environment is as important as your Nursing staff completing their medical gas safety training course.

Assess ward cylinder storage of:

  1. Are the cylinders stored safely?
  2. Is the racking of suitable design?
  3. Do you have enough racking?

If your ward cylinder storage needs attention!! Simply list the locations and count the number of cylinders you need to hold in each area and let us know.

The bracket

  • Medical Gas cylinder Wall Brackets suitable for storing small cylinders “CD” up to “E” size 100mm diameter.
  • Robust Rubber ring to protect cylinders from damage.
  • Ribbed rubber lining in the base for extra cylinder protection.
  • Precut for securing to a wall. Fixings not included.
  • Light Grey BS00A05
  • 1 Cylinder Parking Area sign to be installed above each area.
© 2026 Medical Engineering Systems LimitedTerms & ConditionsRegistered Number 9938596